IP Annals of Prosthodontics and Restorative Dentistry

Print ISSN: 2581-4796

Online ISSN: 2581-480X

IP Annals of Prosthodontics and Restorative Dentistry (APRD) open access, peer-reviewed quarterly journal publishing since 2015 and is published under the Khyati Education and Research Foundation (KERF), is registered as a non-profit society (under the society registration act, 1860), Government of India with the vision of various accredited vocational courses in healthcare, education, paramedical, yoga, publication, teaching and research activity, with the aim of faster and better dissemination of knowledge, we will be publishing the article more...

Article type

Original Article


Article page

7- 15


Authors Details

Divya Mittal*, Balvinder Singh Saluja, Kulwant Singh Ghai, Parag Dua


Article Metrics


View Article As

 


Downlaod Files

   






Article statistics

Viewed: 386

PDF Downloaded: 1296


Comparison of dimensional accuracy of various interocclusal recording materials: An in vitro study


Original Article

Author Details : Divya Mittal*, Balvinder Singh Saluja, Kulwant Singh Ghai, Parag Dua

Volume : 9, Issue : 1, Year : 2023

Article Page : 7-15

https://doi.org/10.18231/j.aprd.2023.003



Suggest article by email

Get Permission

Abstract

Dimensional stability of commonly used interocclusal records is a significant factor for precise articulation of patient's diagnostic and working casts in the fabrication of well fitting prosthesis with satisfactory occlusion. The aim of this study was to measure the dimensional accuracy of modeli g wax, aluwax, addition silicone and modeling wax corrected with zinc oxide eugenol. Total of 80 samples were fabricated. The dimensional accuracy of these materials was tested in three planes i.e. anteroposteriorly, mediolaterally and vertically. The dimensional accuracy in horizontal plane was measured with travelling micro cope and in vertical plane with digital vernier caliper. The values obtained were stati tically analysed y A OVA and Tukey HSD-Honestly significa t difference. olyvi ylsiloxane was observed to be the most dimensionally accurate material and modeli g wax, the least accurate material of all the materials tested.
 

Keywords: Interocclusal records, Dimensional accuracy, Modeling wax, Aluwax, Addition silicone, Zinc oxide eugenol


How to cite : Mittal D, Saluja B S, Ghai K S, Dua P, Comparison of dimensional accuracy of various interocclusal recording materials: An in vitro study. IP Ann Prosthodont Restor Dent 2023;9(1):7-15

This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.