IP Annals of Prosthodontics and Restorative Dentistry

Print ISSN: 2581-4796

Online ISSN: 2581-480X

IP Annals of Prosthodontics and Restorative Dentistry (APRD) open access, peer-reviewed quarterly journal publishing since 2015 and is published under the Khyati Education and Research Foundation (KERF), is registered as a non-profit society (under the society registration act, 1860), Government of India with the vision of various accredited vocational courses in healthcare, education, paramedical, yoga, publication, teaching and research activity, with the aim of faster and better dissemination of knowledge, we will be publishing the article more...

Article type

Original Article


Article page

100-104


Authors Details

Vinod Balla*, Ravindra C Savadi


Article Metrics


View Article As

 


Downlaod Files

   






Article statistics

Viewed: 768

PDF Downloaded: 576


Comparison of the influence of different cements on the compressive strength of Nickel chromium coping and Zirconium oxide coping- An invitro study


Original Article

Author Details : Vinod Balla*, Ravindra C Savadi

Volume : 6, Issue : 2, Year : 2020

Article Page : 100-104

https://doi.org/10.18231/j.aprd.2020.021



Suggest article by email

Get Permission

Abstract

Strength and biocompatibility of any restoration is an important criterion for success and function of any
prosthesis. Despite the high fracture resistance of traditional metal ceramic crowns, limitations are imposed
by esthetic concerns. The objective of this study is to determine whether zirconium dioxide or nickel
chromium copings had better strength when used with two resin based luting cements namely RelyX U100
and Variolink II.
Materials and Methods: A total of 40 copings were fabricated, of which 20 were zirconium oxide copings
made using CAD/CAM technology. The remaining 20 were nickel-chromium copings obtained using Lost
Wax technique. Two resin cements were selected i.e, RelyX U100 universal selfadhesive resin luting cement
(RelyXTM U100, 3M ESPE, Sumar´e, SP, Brazil) and Variolink II resin luting cement (Ivoclar Vivadent,
Schann, Liechtenstein). These cements were mixed and luted on the copings. The copings were seated onto
the steel die using finger pressure for 1 minute and placed under a 2.2 kg standard load for 15 minutes. A
compressive load was applied through a 1/8-inch diameter hardened steel sphere attached to the moving
head of universal testing machine (LR 50K, Lloyds instruments, UK). Load was applied at a crosshead
speed of 0.5 mm per minute until fracture occurred.
Results: It was found that Nickel-Chromium yielded a higher fracture load compared to Zirconia and the
difference in mean fracture load between them was found to be statistically significant (P<0> Copings are found to be a significant factor influencing fracture load. No statistically significant difference
was observed between RelyX and Variolink II cements (P>0.05). Slightly higher mean fracture load was
recorded in Variolink II compared to RelyX.

Keywords: Variolink II, RelyX U100, Nickel-Chromium, Zirconium dioxide.


How to cite : Balla V, Savadi R C, Comparison of the influence of different cements on the compressive strength of Nickel chromium coping and Zirconium oxide coping- An invitro study. IP Ann Prosthodont Restor Dent 2020;6(2):100-104

This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.